Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://dspace.tnpu.edu.ua/handle/123456789/31737
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorVakulenko, Dmytro-
dc.contributor.authorVakulenko, Lyudmyla-
dc.contributor.authorZaspa, Hryhoriy-
dc.contributor.authorLupenko, Serhii-
dc.contributor.authorStetsyuk, Petro-
dc.contributor.authorStovba, Viktor-
dc.date.accessioned2024-01-13T09:29:17Z-
dc.date.available2024-01-13T09:29:17Z-
dc.date.issued2023-
dc.identifier.citationComponents of Oranta-AO software expert system for innovative application of blood pressure monitors / D. Vakulenko [ et al.] // Journal of Reliable Intelligent Environments. 2023. Vol. 9. P. 41–56. https://doi.org/10.1007/s40860-022-00191-4uk_UA
dc.identifier.urihttp://dspace.tnpu.edu.ua/handle/123456789/31737-
dc.description.abstractThe authors developed and substantiated the original methods of arterial oscillography, which were implemented in the developed Oranta-AO information system. The methods of application to the arterial oscillogram registered at measurement of arterial pressure gives the possibility to carry out the supplementary systematic assessment of health, functional state of cardiovascular system, its reserve possibilities etc. The authors also developed an Expert System (based on machinelearning methods) for the differential diagnosis of risks of heart, lung, mental illness and prognosis of some blood parameters. Oranta-AO software system was created based on research results due to methods and algorithms that were innovate. For the mathematical modeling of arterial oscillograms used cyclic random processes. Methods of arterial oscillograms processing based on its model in the form of a cyclic random process was developed. The method of evaluation of the rhythm function of arterial oscillograms and statistical methods for estimating the probabilistic characteristics of arterial oscillograms were developed. To solve the clustering problem, the Python k-means and k-means++ algorithm were used. Oranta-AO information system consists of three interrelated parts: mobile application, computing kernel and web system. Computing kernel and web system are deployed on AWS servers and have been tested already. The developed environment aims to be integrated into every new model of electronic meters in the world. Certification (EN 62304:2014, ISO 13485: 2018) in Ukraine is completed, PCT priority is completed. The next step will be to establish cooperation with manufacturers of electronic pressure monitors, patenting and certification in world.uk_UA
dc.language.isoenuk_UA
dc.subjectBlood pressure monitoruk_UA
dc.subjectHeart rateuk_UA
dc.subjectHealth level ·uk_UA
dc.subjectPulsationuk_UA
dc.subjectInformation systemuk_UA
dc.subjectMachine learninguk_UA
dc.titleComponents of Oranta-AO software expert system for innovative application of blood pressure monitorsuk_UA
dc.typeArticleuk_UA
Розташовується у зібраннях:Статті

Файли цього матеріалу:
Файл Опис РозмірФормат 
Vakulenko_Vakulenko.pdf1,33 MBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.